Air Conditioning Gallery Hawthorn: See the Standard Before You Call

See Why Our Customers Love Us

GET A FREE QUOTE

Split System and Multi-Head Installations

This part of the gallery covers single wall splits and multi-head systems, where one outdoor unit runs several indoor units. Mitsubishi Electric notes that a multi-head setup takes up less space outside, which suits narrow Hawthorn side passages and apartment balconies. Photos of good split system installation work show the indoor head, the pipe and cable route, the drain and the outdoor unit in one frame or a clear sequence, so you can follow the whole run rather than a cropped close-up of a new head.

Indoor Heads Mounted Level, With Covered Pipe Runs

An indoor head should sit level along its top edge, high enough for the air to clear furniture and with room above for the filters to come out. Daikin notes that wall models are mounted high for better airflow and circulation of conditioned air. The pipe, drain and cable run leaving the head should be hidden inside the wall or covered with ducting that is painted or matched to the wall, not left as wrapped pipe taped to the plaster. In a period Hawthorn house with ornate cornices, a good photo shows the head clear of the mouldings and the cover duct following the wall line.

Outdoor Units on Wall Brackets, Pads and Balconies

Outdoor units in a good gallery shot sit level on a solid pad or on a bracket fixed into masonry, with clearance around the coil so the unit can breathe and be serviced. Pipe insulation should be intact and covered where it is exposed to sun. On balconies, the unit should not block a door or drain onto the neighbour below. In the many Hawthorn apartment blocks, the Consumer Affairs Victoria model rules require an owner to get written approval from the owners corporation before changing the external appearance of a lot, so balcony photos often reflect conditions set by that approval.

Ducted Air Conditioning and Zoning

Ducted work is the hardest to photograph well, because most of it sits in the roof space or under the floor. Daikin describes a finished ducted system as one where only the controller, the return air and the discharge grilles are visible inside the home. Gallery shots of ducted air conditioning should therefore show those three things clearly, plus the ceiling around each grille, since a cut that is too large or stained plaster tells you more about the installer than a photo of the unit in the roof.

Ceiling Outlets and Return Air Grilles

Discharge outlets should be cut cleanly into the plaster, sit flush with the ceiling and line up with nearby light fittings or the room's centre line. The return air grille is usually the largest opening, often in a hallway, and needs a clear path back from every room. The Australian Government's YourHome guide notes that a gap under the door between a room and the central return air inlet can create that return path. A gallery photo worth trusting shows the grille, the surrounding ceiling and the doorways, not just a close-up of a new vent.

Zone Controllers and Wall Thermostats

The controller is the one part of a ducted system the household touches every day, so it should be mounted at a sensible height, level, and in a spot that reads the room fairly rather than beside a window or kitchen. Mitsubishi Electric says its zone controller can create up to 4 or 8 separate zones, and that Wi-Fi control needs an extra adaptor. A good handover photo shows the controller labelled by zone, such as living areas and bedrooms, so the zones match how the house is used day and night.

Gas Ducted Heating and Reverse Cycle Heat Pumps

Heating jobs fall into two groups: ducted heating fired by gas, and electric reverse cycle air conditioning, which the Australian Government's Energy Rating site notes is also known as a heat pump. In a gas job the visible finish is the registers, the flue and the paperwork, because gas work done under a licensed gasfitter registered with the Building and Plumbing Commission comes with a compliance certificate. In a heat pump job the visible finish is mostly outside, where the outdoor unit's position decides how it performs and how it sounds to the neighbours.

Floor and Ceiling Heating Registers

Heating registers should sit flush, with clean edges in the floorboards or plaster and no gaps around the frame. YourHome notes that floor outlets are often better than ceiling outlets for heating because warm air naturally rises, and that ceiling outlets can still work when rooms are sealed from draughts. Where a Hawthorn home has floor registers, a good photo shows each one matching the boards and sitting clear of furniture and curtains, so the warm air has room to flow into the room.

Heat Pump Outdoor Units Sited for Airflow and Noise

A reverse cycle outdoor unit works hardest in winter, so it needs open air around it and should not face straight into a neighbour's bedroom window. EPA Victoria's residential noise rules say an air conditioner used for heating should not be heard in another home's habitable room on weekdays before 7 am or after 10 pm, or on weekends and public holidays before 9 am or after 10 pm. The government energy rating label lists a separate outdoor noise rating in dB(A), which helps when comparing quieter models for a tight Hawthorn side boundary.

Servicing, Cleaning and Repair Work

Maintenance work leaves fewer obvious marks than a new install, so photos of it work best as before and after views of the same part. A routine air conditioning service, as QuickAir describes it, covers an indoor coil clean, a drain flush, an outdoor unit clean, operating checks and a refrigerant assessment. Repair photos should show the faulty part, the replacement and the finished wiring. Where refrigerant is handled, the work needs a technician holding an Australian Refrigeration Council licence, so a licence card in shot is a fair thing to ask about.

Washed Coils, Filters and Blower Wheels

Before and after photos of a cleaned split system should show the same filter, coil and barrel fan, with dust and dark build-up gone. Mr Duct Cleaning describes covering the room, fitting a wash bag, foaming and brushing the coil, scrubbing the barrel fan and rinsing at low pressure into the bag rather than onto the wall. Mitsubishi Electric suggests owners clean filters every two weeks in peak seasons, with the heat exchanger cleaned at least once a season. A full aircon cleaning job removes mould, dust and odour build-up from the unit itself.

Cleared Drain Lines and Condensate Trays

A split system or ducted unit makes water as it cools, and that water runs from a tray through a drain line to the outside or a waste point. A clean tray and a clear, sloping drain line are what to look for in photos, together with a drain end that discharges somewhere sensible rather than onto a path or a neighbour's balcony. A blocked drain can show up as water dripping from the indoor head. QuickAir lists a drain flush as part of a full service, so a good service record should mention it.

Replaced Fan Motors, Capacitors and Sensors

Repair photos are most useful when they show the old part beside the new one, the model details on the replacement and the finished connections. Whether the part is a fan motor, a run capacitor or a temperature sensor, the wiring after a repair should be as neat as the factory loom, with no loose joins or tape. Ask for the faulty part to be shown or left behind if you want to see it. Fault finding and air conditioning repair that involves the refrigerant circuit needs a technician holding an ARC licence.

Systems for Shops, Offices and Consulting Rooms

Commercial work in Hawthorn centres on the Glenferrie Road shopping strip and the smaller centres in Church Street, along Auburn Road and at Burwood Road and Power Street, where shops, offices and consulting rooms share walls with neighbours and may answer to building management. Photos of good commercial air conditioning work show indoor units that suit the ceiling, outdoor plant placed where the building allows, and controls a business owner or practice manager can use without a manual. The cost guide What's The Damage lists building management approval and after-hours work as common factors in these jobs, so neat work done out of trading hours is part of the standard.

Ceiling Cassettes and Wall Splits in Trading Spaces

In a shop or office, a ceiling cassette keeps walls free for shelving and signage. Mitsubishi Electric says its PLA-M cassette mounts flush within suspended ceilings and that ceiling cassettes suit open-plan offices and retail spaces needing four-way airflow; for premises without ceiling space, its under-ceiling units mount directly below the ceiling. A good photo shows the cassette centred in a ceiling tile grid and clear of lights and sprinklers. Wall splits suit consulting rooms and small offices, where the head should sit away from the desk or treatment chair so air does not blow straight onto people.

What Good Finished Air Conditioning Work Looks Like

Across every type of job, good finished work shares a few traits that show up in photos and in person. Heads and grilles sit level and square, pipe and cable runs are covered or neatly clipped, outdoor units are secure with clear airflow, electrical work is finished to standard with the right certificate, and the work area is left clean. Before signing off, it is fair to ask for the paperwork, a walk-through of the controller, and a run of the system in both heating and cooling where it has both.

Isolator Switches and Wiring Finished to Standard

Electrical work on an air conditioner should look as neat as the rest of the job: a weatherproof isolator mounted square and labelled near the outdoor unit, cables clipped or enclosed, and no loose joins. Energy Safe Victoria says a Certificate of Electrical Safety is required under the Electricity Safety Act 1998 and that the electrician must give the customer a copy, within 30 days for non-prescribed work. That certificate is part of the finished job, so ask for it rather than relying on a photo of a switch.

Clean Work Areas and a Commissioned System at Handover

A finished job ends with the floor vacuumed, dust sheets lifted, packaging taken away and any plaster dust wiped from sills and furniture. The system should then be commissioned: run in cooling and, where fitted, heating, with airflow and temperature checked at the outlets and the controller set up. What's The Damage lists controls and zone timers set up at handover, and refrigerant recovery from old plant, as items to expect on a quote. Gas work comes with a compliance certificate, which the Building and Plumbing Commission says must reach the customer within five days.

Air Conditioning Installation Armadale
Split System Installation Armadale
Ducted Air Conditioning Armadale
Reverse Cycle Air Conditioning Armadale
Air Conditioning Installation Armadale
Split System Installation Armadale
Ducted Air Conditioning Armadale
Reverse Cycle Air Conditioning Armadale
Air Conditioning Installation Armadale
Split System Installation
Ducted Air Conditioning
Reverse Cycle Air Conditioning
Air Conditioning Installation
Split System Installation Armadale
Ducted Air Conditioning Armadale
Reverse Cycle Air Conditioning Armadale
Evaporative Cooler Service and Repairs Armadale
Air Conditioning Repair Armadale
Emergency Air Conditioning Repair Armadale
Air Conditioning Service Armadale
Aircon Cleaning Armadale
Ducted Heating Armadale
Ducted Heating Service and Repairs Armadale
Commercial Air Conditioning Armadale

Request A Free Quote

GET A FREE QUOTE

TESTIMONIALS

What Our Customers Say About Us